From mboxrd@z Thu Jan 1 00:00:00 1970 From: yixun.lan@amlogic.com (Yixun Lan) Date: Fri, 19 Jan 2018 10:09:26 +0800 Subject: [PATCH] clk: meson: axg: fix the od shift of the sys_pll Message-ID: <20180119020926.246887-1-yixun.lan@amlogic.com> To: linus-amlogic@lists.infradead.org List-Id: linus-amlogic.lists.infradead.org According to datasheet, the od shift of sys_pll is 16, fix the typo which introduced at previous commit. Fixes: 78b4af312f91 ('clk: meson-axg: add clock controller drivers') Signed-off-by: Yixun Lan --- drivers/clk/meson/axg.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/clk/meson/axg.c b/drivers/clk/meson/axg.c index 7988dc8506b0..04a231eaf648 100644 --- a/drivers/clk/meson/axg.c +++ b/drivers/clk/meson/axg.c @@ -64,7 +64,7 @@ static struct meson_clk_pll axg_sys_pll = { }, .od = { .reg_off = HHI_SYS_PLL_CNTL, - .shift = 10, + .shift = 16, .width = 2, }, .lock = &meson_clk_lock, -- 2.15.1