Hi Liam, > Fwiw, the WM8350 has several similar boot up modes. Luckily we can read > back this device to determine mode and any boot loader config. It may > also be required to add any shadow register changes to your > platform_data. i.e. if boot loader does any writes. While I thought about how to achieve that (Specify voltages and convert them back to selector-values? Ask for the selector value? Enforce a complete register set?), I concluded that there are lots of details in here, and I'd spare that for the case when it is actually needed. In our case, it is not. > Btw, have you tried register read back ? The data sheet mentions a > "bidirectional" I2C SDA line implying the device registers can be read > back, even though they are all marked W in the register map. The line itself has the capability of being bidirectional, still the chips has no logic for being read. Page 37 states: "The MAX8660/MAX8661 are write-only devices and recognize the 'write byte' protocol as defined in the SMBus specification and shown in section A of Figure 11..." And to be very sure, I just tried a read -> '-EIO' > > > +The Target Voltage 2 Registers for V3, V4 and V5 are not used by this driver. > > + > > +Note that disabling V3 or V4 has no effect if pin EN34 is driven high (pin and > > +register are ORed, see datasheet). > > + > > Sounds like EN34 status should be in platform_data. Good idea, will implement that. Regards, Wolfram -- Pengutronix e.K. | Wolfram Sang | Industrial Linux Solutions | http://www.pengutronix.de/ |