On Mon, Aug 13, 2012 at 12:57:03PM +0530, Bitan Biswas wrote:
> Hi Guenter,
> 
>  Thank you for the guidance.
> 
> >>
> >>But looking at the hwmon linux documentation, seems the sensor
> >>kernel drivers should report only raw readings.
> >>The raw readings can be converted into required output,
> >>e.g. temperature in this case, by respective user space implementation.
> >>
> >"raw" means the value as reported to the sensor. For example, for an ADC, the
> >raw value means the voltage in mV as seen on the sensor's input pins. This
> >voltage is the voltage to be reported. Converting it to a "real" voltage as,
> >typically, determined by a set of voltage divider resistors should be done in
> >user space.
> >
> >For temperature sensors this is a bit more tricky. Presumably you get readings
> >from a thermistor or similar. The hwmon subsystem includes a driver for NTC
> >thermistors; maybe you can get some ideas from it. Maybe you can even use
> >it and/or extend it to support your hardware.
> 
> The sensor is Tegra3 integrated thermal sensor. It is not a
> thermistor, but gives a counter reading. The expressions to convert
> the counter to temperature use characterization data and certain
> initialization parameters. I looked at the NTC thermistor driver.
> The expressions I need to use to convert counter value to
> temperature would need floating point arguments.
> 
> >
> >>However because of my driver clients being in kernel space, I am
> >>thinking of doing fixed point calculations in the sensor driver
> >>and get the temperature corresponding to raw sensor readings.
> >>
> >>Please let me know if this a correct approach?
> >>
> >Question is really what chip you are using, and how exactly your hardware looks
> >like. Do you use a generic ADC ? If so, is it already supported in the kernel ?
> >How are the thermistor readings converted and reported to SW ?
> 
> I think this is somewhat like an ADC but I need to implement the
> expressions to convert the counter readings to temperature. Using
> fixed point approximations instead of the floating point operands,
> the expressions can be implemented in kernel. The expressions to be
> used for calculation are specific to chip and I could not find a
> existing driver that could support this sensor.
> 
>  There are expressions that can convert the counter readings to
> temperature and vice-versa.
> 1) SW could call the driver callbacks and get the temperature.
> 2) SW could also request temperature thresholds to be configured for
> thermal monitoring.
> 
> The software that may need to use the temperature are some other
> kernel drivers.
> 
> Is it not allowed to implement the counter raw readings to
> temperature in the hwmon sensor driver?
> 
If you look at the NTC driver, that is pretty much exactly what it does. It
accepts Ohm or Volt as input, and calculates a temperature from it. One can
think of a counter reading as to be similar to a resistance reading; if you
do that, you have a good starting point for your driver. You can use either
fixed point approximations, or a table approach as in the NTC driver.

Thanks,
Guenter

      reply	other threads:[~2012-08-13 13:44 UTC|newest]

Thread overview: 4+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2012-08-10 14:18 Bitan Biswas
2012-08-10 18:43 ` [lm-sensors] " Guenter Roeck
2012-08-13  7:27   ` Bitan Biswas
2012-08-13 13:44     ` Guenter Roeck [this message]

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20120813134409.GA31991@roeck-us.net \
    --to=linux@roeck-us.net \
    --cc=bbiswas@nvidia.com \
    --cc=guenter.roeck@ericsson.com \
    --cc=khali@linux-fr.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=lm-sensors@lm-sensors.org \
    --cc=swarren@nvidia.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox

Powered by JetHome