From: "Raj, Ashok" <ashok.raj@intel.com>
To: Alex Williamson <alex.williamson@redhat.com>
Cc: linux-pci@vger.kernel.org, Bjorn Helgaas <bhelgaas@google.com>,
linux-kernel@vger.kernel.org, iommu@lists.linux-foundation.org,
Lu Baolu <baolu.lu@linux.intel.com>,
Darrel Goeddel <DGoeddel@forcepoint.com>,
Mark Scott <mscott@forcepoint.com>,
Romil Sharma <rsharma@forcepoint.com>,
Joerg Roedel <joro@8bytes.org>, Ashok Raj <ashok.raj@intel.com>
Subject: Re: [PATCH] iommu: Relax ACS requirement for RCiEP devices.
Date: Mon, 4 May 2020 23:11:07 -0700 [thread overview]
Message-ID: <20200505061107.GA22974@araj-mobl1.jf.intel.com> (raw)
In-Reply-To: <20200504231936.2bc07fe3@x1.home>
Hi Alex
+ Joerg, accidently missed in the Cc.
On Mon, May 04, 2020 at 11:19:36PM -0600, Alex Williamson wrote:
> On Mon, 4 May 2020 21:42:16 -0700
> Ashok Raj <ashok.raj@intel.com> wrote:
>
> > PCIe Spec recommends we can relax ACS requirement for RCIEP devices.
> >
> > PCIe 5.0 Specification.
> > 6.12 Access Control Services (ACS)
> > Implementation of ACS in RCiEPs is permitted but not required. It is
> > explicitly permitted that, within a single Root Complex, some RCiEPs
> > implement ACS and some do not. It is strongly recommended that Root Complex
> > implementations ensure that all accesses originating from RCiEPs
> > (PFs and VFs) without ACS capability are first subjected to processing by
> > the Translation Agent (TA) in the Root Complex before further decoding and
> > processing. The details of such Root Complex handling are outside the scope
> > of this specification.
> >
> > Since Linux didn't give special treatment to allow this exception, certain
> > RCiEP MFD devices are getting grouped in a single iommu group. This
> > doesn't permit a single device to be assigned to a guest for instance.
> >
> > In one vendor system: Device 14.x were grouped in a single IOMMU group.
> >
> > /sys/kernel/iommu_groups/5/devices/0000:00:14.0
> > /sys/kernel/iommu_groups/5/devices/0000:00:14.2
> > /sys/kernel/iommu_groups/5/devices/0000:00:14.3
> >
> > After the patch:
> > /sys/kernel/iommu_groups/5/devices/0000:00:14.0
> > /sys/kernel/iommu_groups/5/devices/0000:00:14.2
> > /sys/kernel/iommu_groups/6/devices/0000:00:14.3 <<< new group
> >
> > 14.0 and 14.2 are integrated devices, but legacy end points.
> > Whereas 14.3 was a PCIe compliant RCiEP.
> >
> > 00:14.3 Network controller: Intel Corporation Device 9df0 (rev 30)
> > Capabilities: [40] Express (v2) Root Complex Integrated Endpoint, MSI 00
> >
> > This permits assigning this device to a guest VM.
> >
> > Fixes: f096c061f552 ("iommu: Rework iommu_group_get_for_pci_dev()")
> > Signed-off-by: Ashok Raj <ashok.raj@intel.com>
> > To: Joerg Roedel <joro@8bytes.org>
> > To: Bjorn Helgaas <bhelgaas@google.com>
> > Cc: linux-kernel@vger.kernel.org
> > Cc: iommu@lists.linux-foundation.org
> > Cc: Lu Baolu <baolu.lu@linux.intel.com>
> > Cc: Alex Williamson <alex.williamson@redhat.com>
> > Cc: Darrel Goeddel <DGoeddel@forcepoint.com>
> > Cc: Mark Scott <mscott@forcepoint.com>,
> > Cc: Romil Sharma <rsharma@forcepoint.com>
> > Cc: Ashok Raj <ashok.raj@intel.com>
> > ---
> > drivers/iommu/iommu.c | 15 ++++++++++++++-
> > 1 file changed, 14 insertions(+), 1 deletion(-)
> >
> > diff --git a/drivers/iommu/iommu.c b/drivers/iommu/iommu.c
> > index 2b471419e26c..5744bd65f3e2 100644
> > --- a/drivers/iommu/iommu.c
> > +++ b/drivers/iommu/iommu.c
> > @@ -1187,7 +1187,20 @@ static struct iommu_group *get_pci_function_alias_group(struct pci_dev *pdev,
> > struct pci_dev *tmp = NULL;
> > struct iommu_group *group;
> >
> > - if (!pdev->multifunction || pci_acs_enabled(pdev, REQ_ACS_FLAGS))
> > + /*
> > + * PCI Spec 5.0, Section 6.12 Access Control Service
> > + * Implementation of ACS in RCiEPs is permitted but not required.
> > + * It is explicitly permitted that, within a single Root
> > + * Complex, some RCiEPs implement ACS and some do not. It is
> > + * strongly recommended that Root Complex implementations ensure
> > + * that all accesses originating from RCiEPs (PFs and VFs) without
> > + * ACS capability are first subjected to processing by the Translation
> > + * Agent (TA) in the Root Complex before further decoding and
> > + * processing.
> > + */
>
> Is the language here really strong enough to make this change? ACS is
> an optional feature, so being permitted but not required is rather
> meaningless. The spec is also specifically avoiding the words "must"
> or "shall" and even when emphasized with "strongly", we still only have
> a recommendation that may or may not be honored. This seems like a
> weak basis for assuming that RCiEPs universally honor this
> recommendation. Thanks,
>
We are speaking about PCIe spec, where people write it about 5 years ahead
and every vendor tries to massage their product behavior with vague
words like this.. :)
But honestly for any any RCiEP, or even integrated endpoints, there
is no way to send them except up north. These aren't behind a RP.
I did check with couple folks who are part of the SIG, and seem to agree
that ACS treatment for RCiEP's doesn't mean much.
I understand the language isn't strong, but it doesn't seem like ACS should
be a strong requirement for RCiEP's and reasonable to relax.
What are your thoughts?
Cheers,
Ashok
>
> > + if (!pdev->multifunction ||
> > + (pci_pcie_type(pdev) == PCI_EXP_TYPE_RC_END) ||
> > + pci_acs_enabled(pdev, REQ_ACS_FLAGS))
> > return NULL;
> >
> > for_each_pci_dev(tmp) {
>
next prev parent reply other threads:[~2020-05-05 6:11 UTC|newest]
Thread overview: 9+ messages / expand[flat|nested] mbox.gz Atom feed top
2020-05-05 4:42 Ashok Raj
2020-05-05 5:19 ` Alex Williamson
2020-05-05 6:11 ` Raj, Ashok [this message]
2020-05-05 14:05 ` Alex Williamson
2020-05-05 14:56 ` Raj, Ashok
2020-05-05 15:34 ` Alex Williamson
2020-05-26 18:06 ` Raj, Ashok
2020-05-26 18:26 ` Alex Williamson
2020-05-26 18:34 ` Raj, Ashok
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20200505061107.GA22974@araj-mobl1.jf.intel.com \
--to=ashok.raj@intel.com \
--cc=DGoeddel@forcepoint.com \
--cc=alex.williamson@redhat.com \
--cc=baolu.lu@linux.intel.com \
--cc=bhelgaas@google.com \
--cc=iommu@lists.linux-foundation.org \
--cc=joro@8bytes.org \
--cc=linux-kernel@vger.kernel.org \
--cc=linux-pci@vger.kernel.org \
--cc=mscott@forcepoint.com \
--cc=rsharma@forcepoint.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
all inboxes | Powered by JetHome®