Hi Florian, > On 5/30/23 01:39, Lukasz Majewski wrote: > > From: Matthias Schiffer > > > > A mv88e6250 family switch with 2 PHY and RMII ports and > > no PTP support. > > > > Signed-off-by: Matthias Schiffer > > Signed-off-by: Lukasz Majewski > > Reviewed-by: Andrew Lunn > > > --- > [snip] > > > /* List of supported models */ > > enum mv88e6xxx_model { > > + MV88E6020, > > MV88E6085, > > MV88E6095, > > MV88E6097, > > @@ -94,7 +95,7 @@ enum mv88e6xxx_family { > > MV88E6XXX_FAMILY_6097, /* 6046 6085 6096 6097 */ > > MV88E6XXX_FAMILY_6165, /* 6123 6161 6165 */ > > MV88E6XXX_FAMILY_6185, /* 6108 6121 6122 6131 6152 > > 6155 6182 6185 */ > > - MV88E6XXX_FAMILY_6250, /* 6220 6250 */ > > + MV88E6XXX_FAMILY_6250, /* 6220 6250 6020 */ > > über nit: only if you have to resubmit, numbers in ascending order. > I hope that v8 will be the last iteration :-) > Reviewed-by: Florian Fainelli Best regards, Lukasz Majewski -- DENX Software Engineering GmbH, Managing Director: Erika Unter HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email: lukma@denx.de