On Fri, Nov 20, 2026 at 12:26:47PM +0100, ILYAS NHASSE via B4 Relay wrote: > From: ILYAS NHASSE > > The AD7124 signals the end of a conversion on its DOUT/RDY pin, which is > also the SPI MISO line. Using it as an interrupt requires the board to > route that pin to an interrupt-capable input as well, which is not always > possible, e.g. when the ADC sits behind a digital isolator that only > carries the SPI signals. What does this actually mean? Does the isolator only permit data transmission when CS is active? > > The end of a conversion can also be read from the RDY bit of the status > register, so the interrupt is not needed to operate the device. Drop it > from the required properties. > > Signed-off-by: ILYAS NHASSE > --- > Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml | 1 - > 1 file changed, 1 deletion(-) > > diff --git a/Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml b/Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml > index 2e3f84db6..875f46477 100644 > --- a/Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml > +++ b/Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml > @@ -76,7 +76,6 @@ properties: > required: > - compatible > - reg > - - interrupts > > # Can't have both clock input and output at the same time. > not: > > -- > 2.43.0 > >