Bogdan Costescu wrote: > I now understood what the problem was, so I'll put it in words for > posterity: the Link Status bit of the MII Status register needs to be > read twice to first clear the error state (link bit=0) after which the > bit reports the actual value of the link. From the manual: Yes, this is exactly the point. > But I still don't agree with your solution: you are reading the Status > register twice in all cases, which is wrong. What you want is to read it > a second time only after the link was marked as down: a simple check if > bit 2 of the Status register is 0, in which case you issue the second > read. This still means that there will be 2 reads if the link remains > down, but at least there is only 1 read for the case where the link is > up and remains up. I don't think this makes much of a difference in the big picture, but you're certainly right: let's not waste more cycles than we have to. Can we agree on the patch below? -Tommy