I wrote: > This patch fixes this by two separate measures: > a) make sure that no significant interruption occurs between APIC and > TSC reads > b) make sure that the measurement loop isn't significantly longer > than originally intended. Here is a new, simplified version of our patch that only uses measure a). We verified that this is sufficient for accurate calibration. If we fail to determine the start or end time of the calibration correctly 10 times in a row, we will print a critical error message and go on. One might as well argue that this should cause a kernel panic (it is impossible to run on the CPU for only a few cycles without being interrupted by an SMI!), but Cyrill probably won't agree. Martin -- Martin Wilck PRIMERGY System Software Engineer FSC IP ESP DEV 6 Fujitsu Siemens Computers GmbH Heinz-Nixdorf-Ring 1 33106 Paderborn Germany Tel: ++49 5251 8 15113 Fax: ++49 5251 8 20209 Email: mailto:martin.wilck@fujitsu-siemens.com Internet: http://www.fujitsu-siemens.com Company Details: http://www.fujitsu-siemens.com/imprint.html