Hi, my SAMSUNG 250GB drive connected to HPT374 RAID bus controller (SATA) is only working at UDMA 33. I am using HPT36X/37X chipset support (*). And here is what dmesg says: ide5: BM-DMA at 0xc008-0xc00f, BIOS settings: hdk:DMA, hdl:pio hdk: SAMSUNG SP2504C, ATA DISK drive hdk: max request size: 1024KiB hdk: 488397168 sectors (250059 MB) w/8192KiB Cache, CHS=30401/255/63, UDMA(33) hdk: cache flushes supported hdk: lspci: 02:05.0 RAID bus controller: Triones Technologies, Inc. HPT374 (rev 07) Subsystem: Triones Technologies, Inc.: Unknown device 0001 Flags: bus master, 66Mhz, medium devsel, latency 120, IRQ 17 I/O ports at 9c00 [size=8] I/O ports at a000 [size=4] I/O ports at a400 [size=8] I/O ports at a800 [size=4] I/O ports at ac00 [size=256] Expansion ROM at e0020000 [disabled] [size=128K] Capabilities: [60] Power Management version 2 02:05.1 RAID bus controller: Triones Technologies, Inc. HPT374 (rev 07) Subsystem: Triones Technologies, Inc.: Unknown device 0001 Flags: bus master, 66Mhz, medium devsel, latency 120, IRQ 17 I/O ports at b000 [size=8] I/O ports at b400 [size=4] I/O ports at b800 [size=8] I/O ports at bc00 [size=4] I/O ports at c000 [size=256] Capabilities: [60] Power Management version 2 Trying to set UDMA 3-5 directly doesn't work: dmesg: hdk: Speed warnings UDMA 3/4/5 is not functional. hdparm -t /dev/hdk /dev/hdk: Timing buffered disk reads: 42 MB in 3.06 seconds = 13.74 MB/sec Does anyone have a solution to fix this bottleneck? regards, Lukas -- 10 GB Mailbox, 100 FreeSMS/Monat http://www.gmx.net/de/go/topmail +++ GMX - die erste Adresse für Mail, Message, More +++