On Thu, Feb 02, 2023 at 03:11:31PM +0530, Manikanta Guntupalli wrote: > From: Raviteja Narayanam > > repeated start > > When a combined message request comes from user space, the > controller has to initiate repeated start sequence. In standard > mode, this repeated start sequence is corrupted if there is still > data in the Tx FIFO. > > So, always make sure that all the bytes are completely transmitted > out of the FIFO by waiting for TXEMPTY, if the previous message is > of Tx type. > > Signed-off-by: Raviteja Narayanam > Signed-off-by: Manikanta Guntupalli > Acked-by: Michal Simek Applied to for-next, thanks!