From: Lukasz Luba <lukasz.luba@arm.com>
To: "Rafael J. Wysocki" <rafael@kernel.org>
Cc: Amit Kucheria <amitk@kernel.org>,
	"Zhang, Rui" <rui.zhang@intel.com>,
	Linux PM <linux-pm@vger.kernel.org>,
	Linux Kernel Mailing List <linux-kernel@vger.kernel.org>,
	allwinner-opensource-support@allwinnertech.com,
	Stable <stable@vger.kernel.org>,
	Daniel Lezcano <daniel.lezcano@linaro.org>,
	Ionela Voinescu <ionela.voinescu@arm.com>,
	Kant Fan <kant@allwinnertech.com>
Subject: Re: [PATCH v2] thermal: devfreq_cooling: use local ops instead of global ops
Date: Wed, 13 Apr 2022 16:41:26 +0100	[thread overview]
Message-ID: <a931a51f-ea43-846c-0075-086da283ad74@arm.com> (raw)
In-Reply-To: <af2c9715-b085-ac84-22fe-c3f082f889a0@arm.com>



On 4/13/22 16:06, Lukasz Luba wrote:
> 
> 
> On 4/13/22 15:58, Rafael J. Wysocki wrote:
>> On Fri, Mar 25, 2022 at 10:02 AM Lukasz Luba <lukasz.luba@arm.com> wrote:
>>>
>>> Hi Kant,
>>>
>>> On 3/25/22 07:30, Kant Fan wrote:
>>>> Fix access illegal address problem in following condition:
>>>> There are muti devfreq cooling devices in system, some of them has
>>>> em model but other does not, energy model ops such as state2power will
>>>> append to global devfreq_cooling_ops when the cooling device with
>>>> em model register. It makes the cooling device without em model
>>>> also use devfreq_cooling_ops after appending when register later by
>>>> of_devfreq_cooling_register_power() or of_devfreq_cooling_register().
>>>>
>>>> IPA governor regards the cooling devices without em model as a power 
>>>> actor
>>>> because they also have energy model ops, and will access illegal 
>>>> address
>>>> at dfc->em_pd when execute cdev->ops->get_requested_power,
>>>> cdev->ops->state2power or cdev->ops->power2state.
>>>>
>>>> Fixes: 615510fe13bd2 ("thermal: devfreq_cooling: remove old power 
>>>> model and use EM")
>>>> Cc: stable@vger.kernel.org # 5.13+
>>>> Signed-off-by: Kant Fan <kant@allwinnertech.com>
>>>> ---
>>>>    drivers/thermal/devfreq_cooling.c | 25 ++++++++++++++++++-------
>>>>    1 file changed, 18 insertions(+), 7 deletions(-)
>>>>
>>>> diff --git a/drivers/thermal/devfreq_cooling.c 
>>>> b/drivers/thermal/devfreq_cooling.c
>>>> index 4310cb342a9f..d38a80adec73 100644
>>>> --- a/drivers/thermal/devfreq_cooling.c
>>>> +++ b/drivers/thermal/devfreq_cooling.c
>>>> @@ -358,21 +358,28 @@ of_devfreq_cooling_register_power(struct 
>>>> device_node *np, struct devfreq *df,
>>>>        struct thermal_cooling_device *cdev;
>>>>        struct device *dev = df->dev.parent;
>>>>        struct devfreq_cooling_device *dfc;
>>>> +     struct thermal_cooling_device_ops *ops;
>>>>        char *name;
>>>>        int err, num_opps;
>>>>
>>>> -     dfc = kzalloc(sizeof(*dfc), GFP_KERNEL);
>>>> -     if (!dfc)
>>>> +     ops = kmemdup(&devfreq_cooling_ops, sizeof(*ops), GFP_KERNEL);
>>>> +     if (!ops)
>>>>                return ERR_PTR(-ENOMEM);
>>>>
>>>> +     dfc = kzalloc(sizeof(*dfc), GFP_KERNEL);
>>>> +     if (!dfc) {
>>>> +             err = -ENOMEM;
>>>> +             goto free_ops;
>>>> +     }
>>>> +
>>>>        dfc->devfreq = df;
>>>>
>>>>        dfc->em_pd = em_pd_get(dev);
>>>>        if (dfc->em_pd) {
>>>> -             devfreq_cooling_ops.get_requested_power =
>>>> +             ops->get_requested_power =
>>>>                        devfreq_cooling_get_requested_power;
>>>> -             devfreq_cooling_ops.state2power = 
>>>> devfreq_cooling_state2power;
>>>> -             devfreq_cooling_ops.power2state = 
>>>> devfreq_cooling_power2state;
>>>> +             ops->state2power = devfreq_cooling_state2power;
>>>> +             ops->power2state = devfreq_cooling_power2state;
>>>>
>>>>                dfc->power_ops = dfc_power;
>>>>
>>>> @@ -407,8 +414,7 @@ of_devfreq_cooling_register_power(struct 
>>>> device_node *np, struct devfreq *df,
>>>>        if (!name)
>>>>                goto remove_qos_req;
>>>>
>>>> -     cdev = thermal_of_cooling_device_register(np, name, dfc,
>>>> -                                               &devfreq_cooling_ops);
>>>> +     cdev = thermal_of_cooling_device_register(np, name, dfc, ops);
>>>>        kfree(name);
>>>>
>>>>        if (IS_ERR(cdev)) {
>>>> @@ -429,6 +435,8 @@ of_devfreq_cooling_register_power(struct 
>>>> device_node *np, struct devfreq *df,
>>>>        kfree(dfc->freq_table);
>>>>    free_dfc:
>>>>        kfree(dfc);
>>>> +free_ops:
>>>> +     kfree(ops);
>>>>
>>>>        return ERR_PTR(err);
>>>>    }
>>>> @@ -510,11 +518,13 @@ EXPORT_SYMBOL_GPL(devfreq_cooling_em_register);
>>>>    void devfreq_cooling_unregister(struct thermal_cooling_device *cdev)
>>>>    {
>>>>        struct devfreq_cooling_device *dfc;
>>>> +     const struct thermal_cooling_device_ops *ops;
>>>>        struct device *dev;
>>>>
>>>>        if (IS_ERR_OR_NULL(cdev))
>>>>                return;
>>>>
>>>> +     ops = cdev->ops;
>>>>        dfc = cdev->devdata;
>>>>        dev = dfc->devfreq->dev.parent;
>>>>
>>>> @@ -525,5 +535,6 @@ void devfreq_cooling_unregister(struct 
>>>> thermal_cooling_device *cdev)
>>>>
>>>>        kfree(dfc->freq_table);
>>>>        kfree(dfc);
>>>> +     kfree(ops);
>>>>    }
>>>>    EXPORT_SYMBOL_GPL(devfreq_cooling_unregister);
>>>
>>>
>>> Thank you for updating it, LGTM
>>>
>>> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
>>
>> Applied as 5.19 material.
>>
>> Lukasz, this had a conflict with your EM series, please double check
>> if my resolution in the bleeding-edge branch is correct.
> 
> OK, I'll let you know after I fetch and build that branch.

I've read the code and confirm you've do this correctly.
I've also built that branch with ENERGY_MODEL and DEVFREQ_COOLING
configs set - no issues observed.
Later this week I would use it for some other development
so I will test it as well.

Thank you for solving this!

Regards,
Lukasz

      reply	other threads:[~2022-04-13 15:41 UTC|newest]

Thread overview: 5+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2022-03-25  7:30 Kant Fan
2022-03-25  9:01 ` Lukasz Luba
2022-04-13 14:58   ` Rafael J. Wysocki
2022-04-13 15:06     ` Lukasz Luba
2022-04-13 15:41       ` Lukasz Luba [this message]

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=a931a51f-ea43-846c-0075-086da283ad74@arm.com \
    --to=lukasz.luba@arm.com \
    --cc=allwinner-opensource-support@allwinnertech.com \
    --cc=amitk@kernel.org \
    --cc=daniel.lezcano@linaro.org \
    --cc=ionela.voinescu@arm.com \
    --cc=kant@allwinnertech.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pm@vger.kernel.org \
    --cc=rafael@kernel.org \
    --cc=rui.zhang@intel.com \
    --cc=stable@vger.kernel.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox

all inboxes | Powered by JetHome®