On Thu, Nov 26, 2026 at 08:11:06AM -0800, Kyle Hendry via B4 Relay wrote: > From: Kyle Hendry > > The rzn1 system controller has two resets that need to be cleared for the > mii converter to work. They are not directly associated with any clocks > so they need a reset controller to set them. > > They are documented in the PWRCTRL_SWITCHCTRL (0x4000C188) register as: > > Bit 3: RSTN_CLK25 - Active low Reset for Timestamp signal selection logic > Bit 4: RSTN_ETH - Active low Reset for RGMII/RMII Converter (50 MHz). > > Add a reset controller and add resets for those bits. > > Signed-off-by: Kyle Hendry Tested-by: Wolfram Sang