* [PATCH] charger_manager: update charge profile upon temperature zone change
@ 2012-05-07 16:46 Ramakrishna Pallala
0 siblings, 0 replies; only message in thread
From: Ramakrishna Pallala @ 2012-05-07 16:46 UTC (permalink / raw)
To: linux-kernel
Cc: Anton Vorontsov, Anton Vorontsov, MyungJoo Ham, Ramakrishna Pallala
Battery vendors like UER suggest to program Low Charge Voltage in case
of high or low temperatures. So a battery can have different charge profile
with in the battery operating temperature limits.
Next, there could be events like drop or rise in VBUS voltage in that case
we might have to adjust the charge current to stabilize VBUS voltage.
This patch allows the Charger-Manager to adjust the charging parameters
upon events like VBUS rise or drop and allows batteries to have multiple
charge profiles for different temperature zones.
Signed-off-by: Ramakrishna Pallala <ramakrishna.pallala@intel.com>
---
drivers/power/charger-manager.c | 6 +++++-
include/linux/power/charger-manager.h | 5 +++++
2 files changed, 10 insertions(+), 1 deletions(-)
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
index 86935ec..9f46353 100644
--- a/drivers/power/charger-manager.c
+++ b/drivers/power/charger-manager.c
@@ -424,13 +424,17 @@ static void fullbatt_vchk(struct work_struct *work)
static bool _cm_monitor(struct charger_manager *cm)
{
struct charger_desc *desc = cm->desc;
+ bool update_charger = false;
int temp = desc->temperature_out_of_range(&cm->last_temp_mC);
dev_dbg(cm->dev, "monitoring (%2.2d.%3.3dC)\n",
cm->last_temp_mC / 1000, cm->last_temp_mC % 1000);
+ if (desc->charging_zone_changed)
+ update_charger = desc->charging_zone_changed(cm->last_temp_mC);
+
/* It has been stopped or charging already */
- if (!!temp == !!cm->emergency_stop)
+ if ((!!temp == !!cm->emergency_stop) && !update_charger)
return false;
if (temp) {
diff --git a/include/linux/power/charger-manager.h b/include/linux/power/charger-manager.h
index 241065c..302107d 100644
--- a/include/linux/power/charger-manager.h
+++ b/include/linux/power/charger-manager.h
@@ -90,6 +90,10 @@ struct charger_global_desc {
* return_value > 0: overheat
* return_value == 0: normal
* return_value < 0: cold
+ * @charging_zone_changed:
+ * Determine whether charge profile need an update
+ * return_value true if charge profile update required
+ * return_value false if charge profile update is not required
* @measure_battery_temp:
* true: measure battery temperature
* false: measure ambient temperature
@@ -114,6 +118,7 @@ struct charger_desc {
char *psy_fuel_gauge;
int (*temperature_out_of_range)(int *mC);
+ bool (*charging_zone_changed)(int mC);
bool measure_battery_temp;
};
--
1.7.0.4
^ permalink raw reply [flat|nested] only message in thread
only message in thread, other threads:[~2012-05-07 18:13 UTC | newest]
Thread overview: (only message) (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2012-05-07 16:46 [PATCH] charger_manager: update charge profile upon temperature zone change Ramakrishna Pallala
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
all inboxes | Powered by JetHome®