From: Lukasz Luba <lukasz.luba@arm.com>
To: linux-kernel@vger.kernel.org, linux-pm@vger.kernel.org
Cc: daniel.lezcano@linaro.org, amitk@kernel.org, rui.zhang@intel.com,
lukasz.luba@arm.com, viresh.kumar@linaro.org, rafael@kernel.org,
dietmar.eggemann@arm.com, rostedt@goodmis.org, mingo@redhat.com
Subject: [PATCH v2 4/4] thermal: devfreq_cooling: Extend the devfreq_cooling_device with ops
Date: Mon, 13 Jun 2022 13:43:27 +0100 [thread overview]
Message-ID: <20220613124327.30766-5-lukasz.luba@arm.com> (raw)
In-Reply-To: <20220613124327.30766-1-lukasz.luba@arm.com>
Remove unneeded global variable devfreq_cooling_ops which is used only
as a copy pattern. Instead, extend the struct devfreq_cooling_device with
the needed ops structure. This also simplifies the allocation/free code
during the setup/cleanup.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
---
drivers/thermal/devfreq_cooling.c | 27 +++++++++------------------
1 file changed, 9 insertions(+), 18 deletions(-)
diff --git a/drivers/thermal/devfreq_cooling.c b/drivers/thermal/devfreq_cooling.c
index 8c76f9655e57..67b618b1afc8 100644
--- a/drivers/thermal/devfreq_cooling.c
+++ b/drivers/thermal/devfreq_cooling.c
@@ -28,6 +28,7 @@
* struct devfreq_cooling_device - Devfreq cooling device
* devfreq_cooling_device registered.
* @cdev: Pointer to associated thermal cooling device.
+ * @cooling_ops: devfreq callbacks to thermal cooling device ops
* @devfreq: Pointer to associated devfreq device.
* @cooling_state: Current cooling state.
* @freq_table: Pointer to a table with the frequencies sorted in descending
@@ -48,6 +49,7 @@
*/
struct devfreq_cooling_device {
struct thermal_cooling_device *cdev;
+ struct thermal_cooling_device_ops cooling_ops;
struct devfreq *devfreq;
unsigned long cooling_state;
u32 *freq_table;
@@ -290,12 +292,6 @@ static int devfreq_cooling_power2state(struct thermal_cooling_device *cdev,
return 0;
}
-static struct thermal_cooling_device_ops devfreq_cooling_ops = {
- .get_max_state = devfreq_cooling_get_max_state,
- .get_cur_state = devfreq_cooling_get_cur_state,
- .set_cur_state = devfreq_cooling_set_cur_state,
-};
-
/**
* devfreq_cooling_gen_tables() - Generate frequency table.
* @dfc: Pointer to devfreq cooling device.
@@ -363,18 +359,18 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,
char *name;
int err, num_opps;
- ops = kmemdup(&devfreq_cooling_ops, sizeof(*ops), GFP_KERNEL);
- if (!ops)
- return ERR_PTR(-ENOMEM);
dfc = kzalloc(sizeof(*dfc), GFP_KERNEL);
- if (!dfc) {
- err = -ENOMEM;
- goto free_ops;
- }
+ if (!dfc)
+ return ERR_PTR(-ENOMEM);
dfc->devfreq = df;
+ ops = &dfc->cooling_ops;
+ ops->get_max_state = devfreq_cooling_get_max_state;
+ ops->get_cur_state = devfreq_cooling_get_cur_state;
+ ops->set_cur_state = devfreq_cooling_set_cur_state;
+
em = em_pd_get(dev);
if (em && !em_is_artificial(em)) {
dfc->em_pd = em;
@@ -437,8 +433,6 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,
kfree(dfc->freq_table);
free_dfc:
kfree(dfc);
-free_ops:
- kfree(ops);
return ERR_PTR(err);
}
@@ -520,13 +514,11 @@ EXPORT_SYMBOL_GPL(devfreq_cooling_em_register);
void devfreq_cooling_unregister(struct thermal_cooling_device *cdev)
{
struct devfreq_cooling_device *dfc;
- const struct thermal_cooling_device_ops *ops;
struct device *dev;
if (IS_ERR_OR_NULL(cdev))
return;
- ops = cdev->ops;
dfc = cdev->devdata;
dev = dfc->devfreq->dev.parent;
@@ -537,6 +529,5 @@ void devfreq_cooling_unregister(struct thermal_cooling_device *cdev)
kfree(dfc->freq_table);
kfree(dfc);
- kfree(ops);
}
EXPORT_SYMBOL_GPL(devfreq_cooling_unregister);
--
2.17.1
next prev parent reply other threads:[~2022-06-13 17:25 UTC|newest]
Thread overview: 10+ messages / expand[flat|nested] mbox.gz Atom feed top
2022-06-13 12:43 [PATCH v2 0/4] Thermal cpufreq & devfreq cooling minor clean-ups Lukasz Luba
2022-06-13 12:43 ` [PATCH v2 1/4] thermal: cpufreq_cooling: Use private callback ops for each cooling device Lukasz Luba
2022-06-14 2:24 ` Viresh Kumar
2022-06-14 9:50 ` Lukasz Luba
2022-06-13 12:43 ` [PATCH v2 2/4] thermal: cpufreq_cooling : Refactor thermal_power_cpu_get_power tracing Lukasz Luba
2022-06-13 12:43 ` [PATCH v2 3/4] thermal: cpufreq_cooling: Update outdated comments Lukasz Luba
2022-06-13 12:43 ` Lukasz Luba [this message]
2022-06-14 12:51 ` [PATCH v2 0/4] Thermal cpufreq & devfreq cooling minor clean-ups Lukasz Luba
2022-06-14 18:26 ` Daniel Lezcano
2022-06-15 7:47 ` Lukasz Luba
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20220613124327.30766-5-lukasz.luba@arm.com \
--to=lukasz.luba@arm.com \
--cc=amitk@kernel.org \
--cc=daniel.lezcano@linaro.org \
--cc=dietmar.eggemann@arm.com \
--cc=linux-kernel@vger.kernel.org \
--cc=linux-pm@vger.kernel.org \
--cc=mingo@redhat.com \
--cc=rafael@kernel.org \
--cc=rostedt@goodmis.org \
--cc=rui.zhang@intel.com \
--cc=viresh.kumar@linaro.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
all inboxes | Powered by JetHome®