* [PATCH net v2] net: sparx5: start the TOD counters on non-PTP lan969x variants
@ 2026-10-05 5:28 Quentin Freimanis
2026-10-05 9:57 ` Daniel Machon
0 siblings, 1 reply; 2+ messages in thread
From: Quentin Freimanis @ 2026-10-05 5:28 UTC (permalink / raw)
To: netdev
Cc: Daniel Machon, Andrew Lunn, David S. Miller, Eric Dumazet,
Jakub Kicinski, Paolo Abeni, Steen Hegelund, UNGLinuxDriver,
Richard Cochran, linux-arm-kernel, linux-kernel
Currently the base non-PTP-capable lan969x variants don't forward any
Ethernet frames:
$ ip link set eth10 up
$ ip addr add 10.0.0.54/24 dev eth10
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
--- 10.0.0.1 ping statistics ---
7 packets transmitted, 0 packets received, 100% packet loss
$ cat /proc/interrupts | grep fdma
20: 0 GIC-0 120 Level sparx5-fdma
$ ip -s link show dev eth10
RX: bytes packets errors dropped missed mcast
20828 102 0 0 0 72
TX: bytes packets errors dropped carrier collsns
0 0 0 0 0 0
Testing showed that starting the domain 0 TOD counter gets networking
working again, but start all three for consistency with the PTP variants.
Fixes: 207966787b71 ("net: sparx5: add feature support")
Suggested-by: Daniel Machon <daniel.machon@microchip.com>
Signed-off-by: Quentin Freimanis <quentin@q-lab.dev>
---
Changes in v2:
- Drop the TOD start helper and start all three counters (Daniel)
- Fix capitalization in comment explaining why non-PTP parts
need the TOD counters running (Daniel)
- Add test log showing user impact
v1: https://lore.kernel.org/netdev/20260928044955.29647-1-quentin@q-lab.dev/
.../ethernet/microchip/sparx5/sparx5_ptp.c | 28 +++++++++++--------
1 file changed, 16 insertions(+), 12 deletions(-)
diff --git a/drivers/net/ethernet/microchip/sparx5/sparx5_ptp.c b/drivers/net/ethernet/microchip/sparx5/sparx5_ptp.c
index 5953e04ef14e..2826e48af103 100644
--- a/drivers/net/ethernet/microchip/sparx5/sparx5_ptp.c
+++ b/drivers/net/ethernet/microchip/sparx5/sparx5_ptp.c
@@ -622,18 +622,9 @@ int sparx5_ptp_init(struct sparx5 *sparx5)
sparx5->ptp = 1;
}
- if (!sparx5->ptp)
- return 0;
-
- for (i = 0; i < SPARX5_PHC_COUNT; ++i) {
- err = sparx5_ptp_phc_init(sparx5, i, &sparx5_ptp_clock_info);
- if (err)
- return err;
- }
-
- spin_lock_init(&sparx5->ptp_clock_lock);
- spin_lock_init(&sparx5->ptp_ts_id_lock);
- mutex_init(&sparx5->ptp_lock);
+ /* The base, non-PTP-capable lan969x variants need the
+ * first TOD counter running to forward frames.
+ */
/* Disable master counters */
spx5_wr(PTP_PTP_DOM_CFG_PTP_ENA_SET(0), sparx5, PTP_PTP_DOM_CFG);
@@ -657,6 +648,19 @@ int sparx5_ptp_init(struct sparx5 *sparx5)
/* Enable master counters */
spx5_wr(PTP_PTP_DOM_CFG_PTP_ENA_SET(0x7), sparx5, PTP_PTP_DOM_CFG);
+ if (!sparx5->ptp)
+ return 0;
+
+ for (i = 0; i < SPARX5_PHC_COUNT; ++i) {
+ err = sparx5_ptp_phc_init(sparx5, i, &sparx5_ptp_clock_info);
+ if (err)
+ return err;
+ }
+
+ spin_lock_init(&sparx5->ptp_clock_lock);
+ spin_lock_init(&sparx5->ptp_ts_id_lock);
+ mutex_init(&sparx5->ptp_lock);
+
for (i = 0; i < sparx5->data->consts->n_ports; i++) {
port = sparx5->ports[i];
if (!port)
--
2.55.0
^ permalink raw reply [flat|nested] 2+ messages in thread* Re: [PATCH net v2] net: sparx5: start the TOD counters on non-PTP lan969x variants
2026-10-05 5:28 [PATCH net v2] net: sparx5: start the TOD counters on non-PTP lan969x variants Quentin Freimanis
@ 2026-10-05 9:57 ` Daniel Machon
0 siblings, 0 replies; 2+ messages in thread
From: Daniel Machon @ 2026-10-05 9:57 UTC (permalink / raw)
To: Quentin Freimanis
Cc: netdev, Andrew Lunn, David S. Miller, Eric Dumazet,
Jakub Kicinski, Paolo Abeni, Steen Hegelund, UNGLinuxDriver,
Richard Cochran, linux-arm-kernel, linux-kernel
> Currently the base non-PTP-capable lan969x variants don't forward any
> Ethernet frames:
>
> $ ip link set eth10 up
>
> $ ip addr add 10.0.0.54/24 dev eth10
>
> $ ping 10.0.0.1
> PING 10.0.0.1 (10.0.0.1): 56 data bytes
>
> --- 10.0.0.1 ping statistics ---
> 7 packets transmitted, 0 packets received, 100% packet loss
>
> $ cat /proc/interrupts | grep fdma
> 20: 0 GIC-0 120 Level sparx5-fdma
>
> $ ip -s link show dev eth10
> RX: bytes packets errors dropped missed mcast
> 20828 102 0 0 0 72
> TX: bytes packets errors dropped carrier collsns
> 0 0 0 0 0 0
>
> Testing showed that starting the domain 0 TOD counter gets networking
> working again, but start all three for consistency with the PTP variants.
Tested-by: Daniel Machon <daniel.machon@microchip.com>
Reviewed-by: Daniel Machon <daniel.machon@microchip.com>
Thank you for the patch! :-)
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2026-10-05 9:57 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2026-10-05 5:28 [PATCH net v2] net: sparx5: start the TOD counters on non-PTP lan969x variants Quentin Freimanis
2026-10-05 9:57 ` Daniel Machon
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
all inboxes | Powered by JetHome®