* [PATCH v3 1/2] acpi: battery: Introduce Valve steamdeck devices quirk
2026-10-14 20:45 [PATCH v3 0/2] acpi: battery: Query BCT method for steamdeck Umang Jain
@ 2026-10-14 20:45 ` Umang Jain
2026-10-14 20:45 ` [PATCH v3 2/2] acpi: battery: Read Battery charge time for Steamdeck devices Umang Jain
1 sibling, 0 replies; 3+ messages in thread
From: Umang Jain @ 2026-10-14 20:45 UTC (permalink / raw)
To: Rafael J . Wysocki, Len Brown
Cc: linux-acpi, linux-kernel, kernel-dev, Umang Jain
Introduce a battery quirk for Valve Steamdeck devices
ACPI_BATTERY_QUIRK_VALVE_STEAMDECK. This is required to detect
if a low-power supply unit is connected to the device, which can
report charging status through sysfs as "charging", even though in
reality, it is discharging. We shall read Battery Charge Time ("_BCT")
information to handle these cases, in a subsequent commit.
Signed-off-by: Umang Jain <uajain@igalia.com>
---
drivers/acpi/battery.c | 20 ++++++++++++++++++++
1 file changed, 20 insertions(+)
diff --git a/drivers/acpi/battery.c b/drivers/acpi/battery.c
index 670853ec3a4d..fa20900bea0e 100644
--- a/drivers/acpi/battery.c
+++ b/drivers/acpi/battery.c
@@ -94,6 +94,14 @@ enum {
* on a full charge, but showing degradation in full charge cap.
*/
ACPI_BATTERY_QUIRK_DEGRADED_FULL_CHARGE,
+ /*
+ * Valve steamdeck devices can get discharged even when battery status
+ * is charging. This happens typically when low power supply unit is
+ * connected. To accurately determine this scenario, we shall read
+ * battery charge time ("_BCT"). This is the key differentiator to
+ * determine whether the steamdeck is actually charging or not.
+ */
+ ACPI_BATTERY_QUIRK_VALVE_STEAMDECK,
};
struct acpi_battery {
@@ -1057,6 +1065,18 @@ static void acpi_battery_quirks(struct acpi_battery *battery)
set_bit(ACPI_BATTERY_QUIRK_DEGRADED_FULL_CHARGE, &battery->flags);
battery->capacity_now = battery->full_charge_capacity;
}
+
+ if (test_bit(ACPI_BATTERY_QUIRK_VALVE_STEAMDECK, &battery->flags))
+ return;
+
+ if (dmi_name_in_vendors("Valve")) {
+ const char *name;
+
+ name = dmi_get_system_info(DMI_PRODUCT_NAME);
+ if ((name && (!strncmp("Jupiter", name, 7))) ||
+ (name && (!strncmp("Galileo", name, 7))))
+ set_bit(ACPI_BATTERY_QUIRK_VALVE_STEAMDECK, &battery->flags);
+ }
}
static int acpi_battery_update(struct acpi_battery *battery, bool resume)
--
2.55.0
^ permalink raw reply [flat|nested] 3+ messages in thread* [PATCH v3 2/2] acpi: battery: Read Battery charge time for Steamdeck devices
2026-10-14 20:45 [PATCH v3 0/2] acpi: battery: Query BCT method for steamdeck Umang Jain
2026-10-14 20:45 ` [PATCH v3 1/2] acpi: battery: Introduce Valve steamdeck devices quirk Umang Jain
@ 2026-10-14 20:45 ` Umang Jain
1 sibling, 0 replies; 3+ messages in thread
From: Umang Jain @ 2026-10-14 20:45 UTC (permalink / raw)
To: Rafael J . Wysocki, Len Brown
Cc: linux-acpi, linux-kernel, kernel-dev, Umang Jain
Valve steamdeck devices can report battery status as
charging, even when low-powered power supply is connected
to the device. The battery status is reported as charging
through sysfs, even though in reality, it is discharging.
To handle this case, read out Battery charge time ("_BCT")
as it is reported accurately on these devices, hence use that
information for report charging vs discharging status.
Battery charge time ("_BCT") with an eligible power supply unit
will have valid values whereas with a low-powered supply unit,
it shall report ACPI_BATTERY_VALUE_UNKNOWN. Use this as a
differentiator to determine, whether the battery of steamdeck
devices is really charging or not.
Signed-off-by: Umang Jain <uajain@igalia.com>
---
drivers/acpi/battery.c | 25 ++++++++++++++++++++++++-
1 file changed, 24 insertions(+), 1 deletion(-)
diff --git a/drivers/acpi/battery.c b/drivers/acpi/battery.c
index fa20900bea0e..b7818695b6cb 100644
--- a/drivers/acpi/battery.c
+++ b/drivers/acpi/battery.c
@@ -242,7 +242,7 @@ static int acpi_battery_get_property(struct power_supply *psy,
: POWER_SUPPLY_STATUS_DISCHARGING;
return 0;
}
- else if (battery->state & ACPI_BATTERY_STATE_CHARGING)
+ else if (battery->state & ACPI_BATTERY_STATE_CHARGING) {
/* Check the rate and capacity to validate the status. */
if (!acpi_battery_is_full(battery) ||
(battery->rate_now != ACPI_BATTERY_VALUE_UNKNOWN &&
@@ -252,6 +252,29 @@ static int acpi_battery_get_property(struct power_supply *psy,
/* Full and zero rate. */
val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
}
+
+ /*
+ * For Valve Steamdeck devices, evaluate _BCT to determine
+ * if we are really charging.
+ */
+ if (test_bit(ACPI_BATTERY_QUIRK_VALVE_STEAMDECK, &battery->flags) &&
+ acpi_has_method(battery->device->handle, "_BCT")) {
+ unsigned long long bct;
+ acpi_status status;
+ union acpi_object arg0 = { ACPI_TYPE_INTEGER };
+ struct acpi_object_list args = { 1, &arg0 };
+
+ arg0.integer.value = 100;
+ status = acpi_evaluate_integer(battery->device->handle, "_BCT",
+ &args, &bct);
+ if (ACPI_FAILURE(status) || bct > ACPI_UINT32_MAX)
+ acpi_handle_info(battery->device->handle,
+ "_BCT evaluation failed: %s",
+ acpi_format_exception(status));
+ else if (bct == ACPI_BATTERY_VALUE_UNKNOWN)
+ val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+ }
+ }
else if (battery->state & ACPI_BATTERY_STATE_CHARGE_LIMITING)
val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
else if (acpi_battery_is_charged(battery))
--
2.55.0