* [PATCH net-next] net: dsa: b53: mirror BPDUs to CPU port 5 when port 8 is not a CPU port
@ 2026-11-11  6:30 Joseph Telaak
  2026-11-11 10:11 ` Jonas Gorski
  0 siblings, 1 reply; 3+ messages in thread
From: Joseph Telaak @ 2026-11-11  6:30 UTC (permalink / raw)
  To: Florian Fainelli, Jonas Gorski, Andrew Lunn, Vladimir Oltean,
	David S. Miller, Eric Dumazet, Jakub Kicinski, Paolo Abeni
  Cc: netdev, linux-kernel, Joseph Telaak

A BCM531x5 can be connected to the host through its IMP port (8) or
through port 5. With port 5 as the CPU port, b53_brcm_hdr_setup() puts
the switch in dual-IMP mode, in which frames trapped for the CPU, BPDUs
among them, go to port 8 when they come from a LAN port. b53 sets up no
WAN ports, so that is every user port. On boards that use only port 5
and leave port 8 unconnected, BPDUs are lost: STP never sees its peers,
and a loop between two user ports takes the host off the network.

Mirror frames sent to the bridge group address from the user ports to
port 5 instead. The multiport address registers cannot do this, since
the RoboSwitch data sheets resolve reserved multicast before them, and
marking the user ports as WAN ports stopped forwarding between them
when tried. Other frames trapped for the CPU still go to port 8, as the
mirror matches a single destination address. The switch has one mirror,
so tc mirroring is refused on these boards.

This was observed on a BCM53125 board in real use, when both user ports
were cabled into the same LAN. Tested on that board with a host sending
BPDUs into a user port: before, none reached the CPU and the bridge
stayed its own root; after, all of them did, the bridge took the sender
as root, and forwarding between the user ports kept working. No
selftests were run.

Signed-off-by: Joseph Telaak <joseph@telaak.dev>
---
Sent to net-next rather than net because it takes the mirror away from
tc on these boards. I can resend to net with Fixes: 8fab459e69ab ("net:
dsa: b53: Enable Broadcom tags for 531x5/539x families") if you prefer.

Only checked on a BCM53125. BCM5301x boards with port 5 as the only CPU
port may have the same problem, but I could not confirm it.
---
 drivers/net/dsa/b53/b53_common.c | 24 ++++++++++++++++++++++++
 drivers/net/dsa/b53/b53_priv.h   |  1 +
 2 files changed, 25 insertions(+)

diff --git a/drivers/net/dsa/b53/b53_common.c b/drivers/net/dsa/b53/b53_common.c
index a2a5754c413c..6b33775c7598 100644
--- a/drivers/net/dsa/b53/b53_common.c
+++ b/drivers/net/dsa/b53/b53_common.c
@@ -797,6 +797,24 @@ void b53_brcm_hdr_setup(struct dsa_switch *ds, int port)
 		hdr_ctl |= GC_FRM_MGMT_PORT_M;
 	b53_write8(dev, B53_MGMT_PAGE, B53_GLOBAL_CONFIG, hdr_ctl);
 
+	/* With port 5 as the CPU port, a BCM531x5 runs in dual-IMP mode and
+	 * traps BPDUs from LAN ports to port 8. When port 8 is not a CPU
+	 * port, mirror them to port 5 instead. This takes the switch's only
+	 * mirror, so tc mirroring is refused.
+	 */
+	if (tag_en && port == 5 && is531x5(dev) &&
+	    !dsa_is_cpu_port(ds, B53_CPU_PORT)) {
+		b53_write48(dev, B53_MGMT_PAGE, B53_IG_MIR_MAC,
+			    ether_addr_to_u64(eth_stp_addr));
+		b53_write16(dev, B53_MGMT_PAGE, B53_IG_MIR_CTL,
+			    (MIRROR_DA << MIRROR_FILTER_SHIFT) |
+			    (dsa_user_ports(ds) & MIRROR_MASK));
+		b53_write16(dev, B53_MGMT_PAGE, B53_EG_MIR_CTL, 0);
+		b53_write16(dev, B53_MGMT_PAGE, B53_MIR_CAP_CTL,
+			    MIRROR_EN | port);
+		dev->bpdu_mirror = true;
+	}
+
 	/* B53_BRCM_HDR not present on devices with legacy tags */
 	if (dev->tag_protocol == DSA_TAG_PROTO_BRCM_LEGACY ||
 	    dev->tag_protocol == DSA_TAG_PROTO_BRCM_LEGACY_FCS)
@@ -2604,6 +2622,12 @@ int b53_mirror_add(struct dsa_switch *ds, int port,
 	struct b53_device *dev = ds->priv;
 	u16 reg, loc;
 
+	if (dev->bpdu_mirror) {
+		NL_SET_ERR_MSG_MOD(extack,
+				   "The mirror carries BPDUs to CPU port 5");
+		return -EBUSY;
+	}
+
 	if (ingress)
 		loc = B53_IG_MIR_CTL;
 	else
diff --git a/drivers/net/dsa/b53/b53_priv.h b/drivers/net/dsa/b53/b53_priv.h
index c4d2a41c714f..6269c8b3c95a 100644
--- a/drivers/net/dsa/b53/b53_priv.h
+++ b/drivers/net/dsa/b53/b53_priv.h
@@ -170,6 +170,7 @@ struct b53_device {
 
 	/* run time configuration */
 	bool enable_jumbo;
+	bool bpdu_mirror;
 
 	unsigned int num_vlans;
 	struct b53_vlan *vlans;

---
base-commit: d26955e57475434b59d43ba372b2a50d33d5e0ed
change-id: 20261109-b53-bpdu-mirror-d3f66c7a7fd2

Best regards,
--  
Joseph Telaak <joseph@telaak.dev>


^ permalink raw reply	[flat|nested] 3+ messages in thread

* Re: [PATCH net-next] net: dsa: b53: mirror BPDUs to CPU port 5 when port 8 is not a CPU port
  2026-11-11  6:30 [PATCH net-next] net: dsa: b53: mirror BPDUs to CPU port 5 when port 8 is not a CPU port Joseph Telaak
@ 2026-11-11 10:11 ` Jonas Gorski
  2026-11-11 17:22   ` Florian Fainelli
  0 siblings, 1 reply; 3+ messages in thread
From: Jonas Gorski @ 2026-11-11 10:11 UTC (permalink / raw)
  To: Joseph Telaak
  Cc: Florian Fainelli, Andrew Lunn, Vladimir Oltean, David S. Miller,
	Eric Dumazet, Jakub Kicinski, Paolo Abeni, netdev, linux-kernel

Hi,

On Wed, Nov 11, 2026 at 7:31 AM Joseph Telaak <joseph@telaak.dev> wrote:
>
> A BCM531x5 can be connected to the host through its IMP port (8) or
> through port 5. With port 5 as the CPU port, b53_brcm_hdr_setup() puts
> the switch in dual-IMP mode, in which frames trapped for the CPU, BPDUs
> among them, go to port 8 when they come from a LAN port. b53 sets up no
> WAN ports, so that is every user port. On boards that use only port 5
> and leave port 8 unconnected, BPDUs are lost: STP never sees its peers,
> and a loop between two user ports takes the host off the network.
>
> Mirror frames sent to the bridge group address from the user ports to
> port 5 instead. The multiport address registers cannot do this, since
> the RoboSwitch data sheets resolve reserved multicast before them, and
> marking the user ports as WAN ports stopped forwarding between them
> when tried. Other frames trapped for the CPU still go to port 8, as the
> mirror matches a single destination address. The switch has one mirror,
> so tc mirroring is refused on these boards.
>
> This was observed on a BCM53125 board in real use, when both user ports
> were cabled into the same LAN. Tested on that board with a host sending
> BPDUs into a user port: before, none reached the CPU and the bridge
> stayed its own root; after, all of them did, the bridge took the sender
> as root, and forwarding between the user ports kept working. No
> selftests were run.

So on your board only port 5 is wired up, and port 8 is unpopulated
and no way to make it work?

Be aware that more than BPDUs are broken by this, as anything trapped
to CPU is not working. This also affects traffic on ports outside of
the bridge, other trapped packets in the 01:80:c2:00:00:0* range, or
IGMP/MLD snooped packets (or any other L2 protocol snooping).

>
> Signed-off-by: Joseph Telaak <joseph@telaak.dev>
> ---
> Sent to net-next rather than net because it takes the mirror away from
> tc on these boards. I can resend to net with Fixes: 8fab459e69ab ("net:
> dsa: b53: Enable Broadcom tags for 531x5/539x families") if you prefer.
>
> Only checked on a BCM53125. BCM5301x boards with port 5 as the only CPU
> port may have the same problem, but I could not confirm it.

They do, though there it's "easy" to fix by switching to port 8 in the
device tree, since all three ports are AFAIK always hardwired in the
SoC.

> ---
>  drivers/net/dsa/b53/b53_common.c | 24 ++++++++++++++++++++++++
>  drivers/net/dsa/b53/b53_priv.h   |  1 +
>  2 files changed, 25 insertions(+)
>
> diff --git a/drivers/net/dsa/b53/b53_common.c b/drivers/net/dsa/b53/b53_common.c
> index a2a5754c413c..6b33775c7598 100644
> --- a/drivers/net/dsa/b53/b53_common.c
> +++ b/drivers/net/dsa/b53/b53_common.c
> @@ -797,6 +797,24 @@ void b53_brcm_hdr_setup(struct dsa_switch *ds, int port)
>                 hdr_ctl |= GC_FRM_MGMT_PORT_M;
>         b53_write8(dev, B53_MGMT_PAGE, B53_GLOBAL_CONFIG, hdr_ctl);
>
> +       /* With port 5 as the CPU port, a BCM531x5 runs in dual-IMP mode and
> +        * traps BPDUs from LAN ports to port 8. When port 8 is not a CPU
> +        * port, mirror them to port 5 instead. This takes the switch's only
> +        * mirror, so tc mirroring is refused.
> +        */
> +       if (tag_en && port == 5 && is531x5(dev) &&
> +           !dsa_is_cpu_port(ds, B53_CPU_PORT)) {

So this should be extended to all dual IMP capable chips, because they
are all equally affected.

> +               b53_write48(dev, B53_MGMT_PAGE, B53_IG_MIR_MAC,
> +                           ether_addr_to_u64(eth_stp_addr));
> +               b53_write16(dev, B53_MGMT_PAGE, B53_IG_MIR_CTL,
> +                           (MIRROR_DA << MIRROR_FILTER_SHIFT) |
> +                           (dsa_user_ports(ds) & MIRROR_MASK));
> +               b53_write16(dev, B53_MGMT_PAGE, B53_EG_MIR_CTL, 0);
> +               b53_write16(dev, B53_MGMT_PAGE, B53_MIR_CAP_CTL,
> +                           MIRROR_EN | port);

Have you tried a catch-all port 8 egress to port 5 mirror? If that
happens to work, it should catch any trapped traffic. May not work
while the port is disabled in software though.

> +               dev->bpdu_mirror = true;
> +       }
> +
>         /* B53_BRCM_HDR not present on devices with legacy tags */
>         if (dev->tag_protocol == DSA_TAG_PROTO_BRCM_LEGACY ||
>             dev->tag_protocol == DSA_TAG_PROTO_BRCM_LEGACY_FCS)
> @@ -2604,6 +2622,12 @@ int b53_mirror_add(struct dsa_switch *ds, int port,
>         struct b53_device *dev = ds->priv;
>         u16 reg, loc;
>
> +       if (dev->bpdu_mirror) {
> +               NL_SET_ERR_MSG_MOD(extack,
> +                                  "The mirror carries BPDUs to CPU port 5");
> +               return -EBUSY;

I think this should be rather -EOPNOTSUPP, as with this setup we will
never be able to support it; -EBUSY feels more like a temporary state.

Best regards,
Jonas

^ permalink raw reply	[flat|nested] 3+ messages in thread

* Re: [PATCH net-next] net: dsa: b53: mirror BPDUs to CPU port 5 when port 8 is not a CPU port
  2026-11-11 10:11 ` Jonas Gorski
@ 2026-11-11 17:22   ` Florian Fainelli
  0 siblings, 0 replies; 3+ messages in thread
From: Florian Fainelli @ 2026-11-11 17:22 UTC (permalink / raw)
  To: Jonas Gorski, Joseph Telaak
  Cc: Andrew Lunn, Vladimir Oltean, David S. Miller, Eric Dumazet,
	Jakub Kicinski, Paolo Abeni, netdev, linux-kernel

On 11/11/26 02:11, Jonas Gorski wrote:
> Hi,
> 
> On Wed, Nov 11, 2026 at 7:31 AM Joseph Telaak <joseph@telaak.dev> wrote:
>>
>> A BCM531x5 can be connected to the host through its IMP port (8) or
>> through port 5. With port 5 as the CPU port, b53_brcm_hdr_setup() puts
>> the switch in dual-IMP mode, in which frames trapped for the CPU, BPDUs
>> among them, go to port 8 when they come from a LAN port. b53 sets up no
>> WAN ports, so that is every user port. On boards that use only port 5
>> and leave port 8 unconnected, BPDUs are lost: STP never sees its peers,
>> and a loop between two user ports takes the host off the network.
>>
>> Mirror frames sent to the bridge group address from the user ports to
>> port 5 instead. The multiport address registers cannot do this, since
>> the RoboSwitch data sheets resolve reserved multicast before them, and
>> marking the user ports as WAN ports stopped forwarding between them
>> when tried. Other frames trapped for the CPU still go to port 8, as the
>> mirror matches a single destination address. The switch has one mirror,
>> so tc mirroring is refused on these boards.
>>
>> This was observed on a BCM53125 board in real use, when both user ports
>> were cabled into the same LAN. Tested on that board with a host sending
>> BPDUs into a user port: before, none reached the CPU and the bridge
>> stayed its own root; after, all of them did, the bridge took the sender
>> as root, and forwarding between the user ports kept working. No
>> selftests were run.
> 
> So on your board only port 5 is wired up, and port 8 is unpopulated
> and no way to make it work?
> 
> Be aware that more than BPDUs are broken by this, as anything trapped
> to CPU is not working. This also affects traffic on ports outside of
> the bridge, other trapped packets in the 01:80:c2:00:00:0* range, or
> IGMP/MLD snooped packets (or any other L2 protocol snooping).
> 
>>
>> Signed-off-by: Joseph Telaak <joseph@telaak.dev>
>> ---
>> Sent to net-next rather than net because it takes the mirror away from
>> tc on these boards. I can resend to net with Fixes: 8fab459e69ab ("net:
>> dsa: b53: Enable Broadcom tags for 531x5/539x families") if you prefer.
>>
>> Only checked on a BCM53125. BCM5301x boards with port 5 as the only CPU
>> port may have the same problem, but I could not confirm it.
> 
> They do, though there it's "easy" to fix by switching to port 8 in the
> device tree, since all three ports are AFAIK always hardwired in the
> SoC.

Yes, I have a series of patches doing that, because using port 5 is just 
not working for everything.

> 
>> ---
>>   drivers/net/dsa/b53/b53_common.c | 24 ++++++++++++++++++++++++
>>   drivers/net/dsa/b53/b53_priv.h   |  1 +
>>   2 files changed, 25 insertions(+)
>>
>> diff --git a/drivers/net/dsa/b53/b53_common.c b/drivers/net/dsa/b53/b53_common.c
>> index a2a5754c413c..6b33775c7598 100644
>> --- a/drivers/net/dsa/b53/b53_common.c
>> +++ b/drivers/net/dsa/b53/b53_common.c
>> @@ -797,6 +797,24 @@ void b53_brcm_hdr_setup(struct dsa_switch *ds, int port)
>>                  hdr_ctl |= GC_FRM_MGMT_PORT_M;
>>          b53_write8(dev, B53_MGMT_PAGE, B53_GLOBAL_CONFIG, hdr_ctl);
>>
>> +       /* With port 5 as the CPU port, a BCM531x5 runs in dual-IMP mode and
>> +        * traps BPDUs from LAN ports to port 8. When port 8 is not a CPU
>> +        * port, mirror them to port 5 instead. This takes the switch's only
>> +        * mirror, so tc mirroring is refused.
>> +        */
>> +       if (tag_en && port == 5 && is531x5(dev) &&
>> +           !dsa_is_cpu_port(ds, B53_CPU_PORT)) {
> 
> So this should be extended to all dual IMP capable chips, because they
> are all equally affected.
> 
>> +               b53_write48(dev, B53_MGMT_PAGE, B53_IG_MIR_MAC,
>> +                           ether_addr_to_u64(eth_stp_addr));
>> +               b53_write16(dev, B53_MGMT_PAGE, B53_IG_MIR_CTL,
>> +                           (MIRROR_DA << MIRROR_FILTER_SHIFT) |
>> +                           (dsa_user_ports(ds) & MIRROR_MASK));
>> +               b53_write16(dev, B53_MGMT_PAGE, B53_EG_MIR_CTL, 0);
>> +               b53_write16(dev, B53_MGMT_PAGE, B53_MIR_CAP_CTL,
>> +                           MIRROR_EN | port);
> 
> Have you tried a catch-all port 8 egress to port 5 mirror? If that
> happens to work, it should catch any trapped traffic. May not work
> while the port is disabled in software though.

We could also try to use the CFP to perform a full redirection to port 8.

> 
>> +               dev->bpdu_mirror = true;
>> +       }
>> +
>>          /* B53_BRCM_HDR not present on devices with legacy tags */
>>          if (dev->tag_protocol == DSA_TAG_PROTO_BRCM_LEGACY ||
>>              dev->tag_protocol == DSA_TAG_PROTO_BRCM_LEGACY_FCS)
>> @@ -2604,6 +2622,12 @@ int b53_mirror_add(struct dsa_switch *ds, int port,
>>          struct b53_device *dev = ds->priv;
>>          u16 reg, loc;
>>
>> +       if (dev->bpdu_mirror) {
>> +               NL_SET_ERR_MSG_MOD(extack,
>> +                                  "The mirror carries BPDUs to CPU port 5");
>> +               return -EBUSY;
> 
> I think this should be rather -EOPNOTSUPP, as with this setup we will
> never be able to support it; -EBUSY feels more like a temporary state.

Agreed.
-- 
Florian

^ permalink raw reply	[flat|nested] 3+ messages in thread

end of thread, other threads:[~2026-11-11 17:22 UTC | newest]

Thread overview: 3+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2026-11-11  6:30 [PATCH net-next] net: dsa: b53: mirror BPDUs to CPU port 5 when port 8 is not a CPU port Joseph Telaak
2026-11-11 10:11 ` Jonas Gorski
2026-11-11 17:22   ` Florian Fainelli

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox

all inboxes | Powered by JetHome®