mirror of https://lore.kernel.org/lkml/
 help / color / mirror / Atom feed
* [PATCH v2] arm_mpam: resctrl: Limit num_rmids to the CLOSIDs in use
@ 2026-11-05 12:33 Jinjie Ruan
  2026-11-05 14:12 ` Ben Horgan
  0 siblings, 1 reply; 3+ messages in thread
From: Jinjie Ruan @ 2026-11-05 12:33 UTC (permalink / raw)
  To: tony.luck, reinette.chatre, Dave.Martin, james.morse, babu.moger,
	tglx, mingo, bp, dave.hansen, hpa, ben.horgan, fenghuay, jic23,
	zengheng4, gshan, x86, linux-kernel, linux-arm-kernel
  Cc: ruanjinjie

On MPAM an RMID is a PMG within a PARTID, so resctrl can only allocate
the PMGs of the CLOSIDs it uses. info/L3_MON/num_rmids is instead set
to the whole PARTID and PMG space when the monitors are initialised,
and halved when CDP is enabled. It reports more RMIDs than resctrl can
allocate in two cases:

- With CDP each CLOSID takes two PARTIDs, and resctrl halves the
  CLOSID count rounding down, while MPAM halves the whole RMID space.
  With 5 PARTIDs and 2 PMGs resctrl has 2 CLOSIDs and 4 RMIDs, but
  num_rmids reads 5. The count is too high whenever the number of
  PARTIDs is odd and there is more than one PMG.

- On a monitor-only system there are no control groups and resctrl
  only uses the default CLOSID, but num_rmids still covers every
  PARTID. With 5 PARTIDs and 2 PMGs it reads 10 while only 2 RMIDs
  can be allocated.

RMID allocation is limited to the CLOSIDs in use, so only the value
reported to userspace is too high. Creating as many monitor groups as
num_rmids allows fails with -ENOSPC before that number is reached.

Let resctrl tell the architecture how many CLOSIDs it uses on every
mount. Add resctrl_arch_set_mon_rmid_count(), called after closid_init()
and before the info files are created, and have MPAM report
(pmg_max + 1) RMIDs for each CLOSID. The CLOSID count already accounts
for CDP, as schemata_list_add() halves it when CDP is enabled, so drop
the halving in resctrl_arch_set_cdp_enabled(). A monitor-only system
passes 1 for the default CLOSID. On x86 the RMIDs do not depend on the
CLOSIDs and the hook does nothing.

Fixes: 264c285999fc ("arm_mpam: resctrl: Add monitor initialisation and domain boilerplate")
Signed-off-by: Jinjie Ruan <ruanjinjie@huawei.com>
Cc: <stable@vger.kernel.org> # 7.1.x
Cc: James Morse <james.morse@arm.com>
Cc: Ben Horgan <ben.horgan@arm.com>
Cc: Reinette Chatre <reinette.chatre@intel.com>
Cc: Fenghua Yu <fenghuay@nvidia.com>
---
v2:
- Use the "arm_mpam: resctrl:" prefix.
- Also fix num_rmids on monitor-only systems, as Ben suggested: add
  resctrl_arch_set_mon_rmid_count() so resctrl reports the number of
  CLOSIDs it uses, and remove the CDP-only rounding.
- Retitle from "arm_mpam: Round the CDP RMID count down to whole CLOSIDs".
- v1: https://lore.kernel.org/all/20261104101622.563280-1-ruanjinjie@huawei.com/
---
 arch/x86/include/asm/resctrl.h |  3 +++
 drivers/resctrl/mpam_resctrl.c | 18 ++++++++++++------
 fs/resctrl/rdtgroup.c          |  2 ++
 include/linux/resctrl.h        |  1 +
 4 files changed, 18 insertions(+), 6 deletions(-)

diff --git a/arch/x86/include/asm/resctrl.h b/arch/x86/include/asm/resctrl.h
index 8f6edcdcfd87..50165027b92d 100644
--- a/arch/x86/include/asm/resctrl.h
+++ b/arch/x86/include/asm/resctrl.h
@@ -164,6 +164,9 @@ static inline bool resctrl_arch_match_rmid(struct task_struct *tsk, u32 ignored,
 	return READ_ONCE(tsk->rmid) == rmid;
 }
 
+/* RMIDs are independent of CLOSIDs on x86. */
+static inline void resctrl_arch_set_mon_rmid_count(u32 num_closid) { }
+
 static inline void resctrl_arch_sched_in(struct task_struct *tsk)
 {
 	if (static_branch_likely(&rdt_enable_key))
diff --git a/drivers/resctrl/mpam_resctrl.c b/drivers/resctrl/mpam_resctrl.c
index 5468367776e2..cca9568bab70 100644
--- a/drivers/resctrl/mpam_resctrl.c
+++ b/drivers/resctrl/mpam_resctrl.c
@@ -217,11 +217,6 @@ int resctrl_arch_set_cdp_enabled(enum resctrl_res_level rid, bool enable)
 	cdp_enabled = enable;
 	mpam_resctrl_controls[rid].cdp_enabled = enable;
 
-	if (enable)
-		l3->mon.num_rmid = resctrl_arch_system_num_rmid_idx() / 2;
-	else
-		l3->mon.num_rmid = resctrl_arch_system_num_rmid_idx();
-
 	/* The mbw_max feature can't hide cdp as it's a per-partid maximum. */
 	if (cdp_enabled && !mpam_resctrl_controls[RDT_RESOURCE_MBA].cdp_enabled)
 		mpam_resctrl_controls[RDT_RESOURCE_MBA].resctrl_res.alloc_capable = false;
@@ -279,6 +274,16 @@ u32 resctrl_arch_system_num_rmid_idx(void)
 	return (mpam_pmg_max + 1) * (mpam_partid_max + 1);
 }
 
+void resctrl_arch_set_mon_rmid_count(u32 num_closid)
+{
+	struct rdt_resource *l3 = &mpam_resctrl_controls[RDT_RESOURCE_L3].resctrl_res;
+
+	if (!l3->mon_capable)
+		return;
+
+	l3->mon.num_rmid = (mpam_pmg_max + 1) * num_closid;
+}
+
 u32 resctrl_arch_rmid_idx_encode(u32 closid, u32 rmid)
 {
 	return closid * (mpam_pmg_max + 1) + rmid;
@@ -1350,7 +1355,8 @@ static int mpam_resctrl_monitor_init(struct mpam_resctrl_mon *mon,
 	 * each control group. Hence, advertise the whole rmid_idx space even
 	 * though each control group has its own pmg/rmid space. Unfortunately,
 	 * this does mean userspace needs to know the architecture to correctly
-	 * interpret this value.
+	 * interpret this value. resctrl_arch_set_mon_rmid_count() replaces it
+	 * with the RMIDs of the CLOSIDs in use when resctrl is mounted.
 	 */
 	l3->mon.num_rmid = resctrl_arch_system_num_rmid_idx();
 
diff --git a/fs/resctrl/rdtgroup.c b/fs/resctrl/rdtgroup.c
index 106e78fb1f1d..2335dd7054ca 100644
--- a/fs/resctrl/rdtgroup.c
+++ b/fs/resctrl/rdtgroup.c
@@ -3214,6 +3214,8 @@ static int rdt_get_tree(struct fs_context *fc)
 	if (ret)
 		goto out_schemata_free;
 
+	resctrl_arch_set_mon_rmid_count(closids_supported() ?: 1);
+
 	if (resctrl_arch_mon_capable())
 		flags |= RFTYPE_MON;
 
diff --git a/include/linux/resctrl.h b/include/linux/resctrl.h
index 10dfdca7f4bf..4a78f2e60bdf 100644
--- a/include/linux/resctrl.h
+++ b/include/linux/resctrl.h
@@ -417,6 +417,7 @@ static inline u32 resctrl_get_default_ctrl(struct rdt_resource *r)
 /* The number of closid supported by this resource regardless of CDP */
 u32 resctrl_arch_get_num_closid(struct rdt_resource *r);
 u32 resctrl_arch_system_num_rmid_idx(void);
+void resctrl_arch_set_mon_rmid_count(u32 num_closid);
 int resctrl_arch_update_domains(struct rdt_resource *r, u32 closid);
 
 bool resctrl_enable_mon_event(enum resctrl_event_id eventid, bool any_cpu,
-- 
2.34.1


^ permalink raw reply	[flat|nested] 3+ messages in thread

end of thread, other threads:[~2026-11-06  6:31 UTC | newest]

Thread overview: 3+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2026-11-05 12:33 [PATCH v2] arm_mpam: resctrl: Limit num_rmids to the CLOSIDs in use Jinjie Ruan
2026-11-05 14:12 ` Ben Horgan
2026-11-06  6:30   ` Jinjie Ruan

This is a public inbox, see mirroring instructions