* [PATCH] dmaengine: pl330: drop only the runtime PM reference a channel holds
@ 2026-10-28 11:28 Krzysztof Sokołowski via B4 Relay
2026-10-28 14:35 ` Frank Li
0 siblings, 1 reply; 3+ messages in thread
From: Krzysztof Sokołowski via B4 Relay @ 2026-10-28 11:28 UTC (permalink / raw)
To: Vinod Koul
Cc: Frank Li, dmaengine, linux-kernel, stable, Krzysztof Sokołowski
From: Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
pl330_tasklet() drops a runtime PM reference when the channel's work
list is empty, without checking that the channel still holds one.
pl330_terminate_all() drops that reference too (power_down =
pch->active) and clears pch->active. If a completion schedules the
tasklet and a client terminates the channel before the tasklet runs, the
tasklet finds an empty work list and drops the reference a second time:
Runtime PM usage count underflow!
after which the controller can be runtime suspended while still in use.
Seen on an RK3128 board (dw_mmc using the PL330 for SD transfers) under
combined SD and USB load, where the dw_mmc error path terminates the
channel; the underflow was followed by "pl330_update:1678 Unexpected!"
and a failure to request the DMA channel again.
Take power_down from pch->active in the tasklet, as pl330_terminate_all()
does, so the reference taken in pl330_issue_pending() is dropped once.
Fixes: 5c9e6c2b2ba3 ("dmaengine: pl330: Fix runtime PM support for terminated transfers")
Cc: stable@vger.kernel.org
Signed-off-by: Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
---
drivers/dma/pl330.c | 7 ++++++-
1 file changed, 6 insertions(+), 1 deletion(-)
diff --git a/drivers/dma/pl330.c b/drivers/dma/pl330.c
index c2d0b47..b0eced8 100644
--- a/drivers/dma/pl330.c
+++ b/drivers/dma/pl330.c
@@ -2090,7 +2090,12 @@ static void pl330_tasklet(struct tasklet_struct *t)
spin_lock(&pch->thread->dmac->lock);
_stop(pch->thread);
spin_unlock(&pch->thread->dmac->lock);
- power_down = true;
+ /*
+ * Drop the runtime PM reference only if this channel still
+ * holds it: pl330_terminate_all() may already have dropped it
+ * while this tasklet was scheduled.
+ */
+ power_down = pch->active;
pch->active = false;
} else {
/* Make sure the PL330 Channel thread is active */
---
base-commit: aff5e6a77fc69a7c490246465940d18422d7c631
change-id: 20261028-pl330-runtime-pm-b5a30050b2f5
Best regards,
--
Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
^ permalink raw reply [flat|nested] 3+ messages in thread
* Re: [PATCH] dmaengine: pl330: drop only the runtime PM reference a channel holds
2026-10-28 11:28 [PATCH] dmaengine: pl330: drop only the runtime PM reference a channel holds Krzysztof Sokołowski via B4 Relay
@ 2026-10-28 14:35 ` Frank Li
2026-10-28 17:03 ` Krzysztof Sokołowski
0 siblings, 1 reply; 3+ messages in thread
From: Frank Li @ 2026-10-28 14:35 UTC (permalink / raw)
To: krzysiek.sokolowski; +Cc: Vinod Koul, Frank Li, dmaengine, linux-kernel, stable
On Wed, Oct 28, 2026 at 12:28:11PM +0100, Krzysztof Sokołowski via B4 Relay wrote:
> [You don't often get email from devnull+krzysiek.sokolowski.gmail.com@kernel.org. Learn why this is important at https://aka.ms/LearnAboutSenderIdentification ]
>
> From: Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
>
> pl330_tasklet() drops a runtime PM reference when the channel's work
> list is empty, without checking that the channel still holds one.
> pl330_terminate_all() drops that reference too (power_down =
> pch->active) and clears pch->active. If a completion schedules the
> tasklet and a client terminates the channel before the tasklet runs, the
> tasklet finds an empty work list and drops the reference a second time:
>
> Runtime PM usage count underflow!
>
> after which the controller can be runtime suspended while still in use.
>
> Seen on an RK3128 board (dw_mmc using the PL330 for SD transfers) under
> combined SD and USB load, where the dw_mmc error path terminates the
> channel; the underflow was followed by "pl330_update:1678 Unexpected!"
> and a failure to request the DMA channel again.
>
> Take power_down from pch->active in the tasklet, as pl330_terminate_all()
> does, so the reference taken in pl330_issue_pending() is dropped once.
>
> Fixes: 5c9e6c2b2ba3 ("dmaengine: pl330: Fix runtime PM support for terminated transfers")
> Cc: stable@vger.kernel.org
> Signed-off-by: Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
> ---
The same patch at
https://patchwork.kernel.org/project/linux-dmaengine/patch/20261015-review-pl330-pm-original-v3-v3-1-5be09f37df77@crepuse.com/
Frank
> drivers/dma/pl330.c | 7 ++++++-
> 1 file changed, 6 insertions(+), 1 deletion(-)
>
> diff --git a/drivers/dma/pl330.c b/drivers/dma/pl330.c
> index c2d0b47..b0eced8 100644
> --- a/drivers/dma/pl330.c
> +++ b/drivers/dma/pl330.c
> @@ -2090,7 +2090,12 @@ static void pl330_tasklet(struct tasklet_struct *t)
> spin_lock(&pch->thread->dmac->lock);
> _stop(pch->thread);
> spin_unlock(&pch->thread->dmac->lock);
> - power_down = true;
> + /*
> + * Drop the runtime PM reference only if this channel still
> + * holds it: pl330_terminate_all() may already have dropped it
> + * while this tasklet was scheduled.
> + */
> + power_down = pch->active;
> pch->active = false;
> } else {
> /* Make sure the PL330 Channel thread is active */
>
> ---
> base-commit: aff5e6a77fc69a7c490246465940d18422d7c631
> change-id: 20261028-pl330-runtime-pm-b5a30050b2f5
>
> Best regards,
> --
> Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
>
>
^ permalink raw reply [flat|nested] 3+ messages in thread
* Re: [PATCH] dmaengine: pl330: drop only the runtime PM reference a channel holds
2026-10-28 14:35 ` Frank Li
@ 2026-10-28 17:03 ` Krzysztof Sokołowski
0 siblings, 0 replies; 3+ messages in thread
From: Krzysztof Sokołowski @ 2026-10-28 17:03 UTC (permalink / raw)
To: Frank Li; +Cc: Vinod Koul, Frank Li, dmaengine, linux-kernel, stable
W dniu 28.10.2026 o 15:35, Frank Li pisze:
> On Wed, Oct 28, 2026 at 12:28:11PM +0100, Krzysztof Sokołowski via B4 Relay wrote:
>> [You don't often get email from devnull+krzysiek.sokolowski.gmail.com@kernel.org. Learn why this is important at https://aka.ms/LearnAboutSenderIdentification ]
>>
>> From: Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
>>
>> pl330_tasklet() drops a runtime PM reference when the channel's work
>> list is empty, without checking that the channel still holds one.
>> pl330_terminate_all() drops that reference too (power_down =
>> pch->active) and clears pch->active. If a completion schedules the
>> tasklet and a client terminates the channel before the tasklet runs, the
>> tasklet finds an empty work list and drops the reference a second time:
>>
>> Runtime PM usage count underflow!
>>
>> after which the controller can be runtime suspended while still in use.
>>
>> Seen on an RK3128 board (dw_mmc using the PL330 for SD transfers) under
>> combined SD and USB load, where the dw_mmc error path terminates the
>> channel; the underflow was followed by "pl330_update:1678 Unexpected!"
>> and a failure to request the DMA channel again.
>>
>> Take power_down from pch->active in the tasklet, as pl330_terminate_all()
>> does, so the reference taken in pl330_issue_pending() is dropped once.
>>
>> Fixes: 5c9e6c2b2ba3 ("dmaengine: pl330: Fix runtime PM support for terminated transfers")
>> Cc: stable@vger.kernel.org
>> Signed-off-by: Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
>> ---
> The same patch at
> https://patchwork.kernel.org/project/linux-dmaengine/patch/20261015-review-pl330-pm-original-v3-v3-1-5be09f37df77@crepuse.com/
>
> Frank
>> drivers/dma/pl330.c | 7 ++++++-
>> 1 file changed, 6 insertions(+), 1 deletion(-)
>>
>> diff --git a/drivers/dma/pl330.c b/drivers/dma/pl330.c
>> index c2d0b47..b0eced8 100644
>> --- a/drivers/dma/pl330.c
>> +++ b/drivers/dma/pl330.c
>> @@ -2090,7 +2090,12 @@ static void pl330_tasklet(struct tasklet_struct *t)
>> spin_lock(&pch->thread->dmac->lock);
>> _stop(pch->thread);
>> spin_unlock(&pch->thread->dmac->lock);
>> - power_down = true;
>> + /*
>> + * Drop the runtime PM reference only if this channel still
>> + * holds it: pl330_terminate_all() may already have dropped it
>> + * while this tasklet was scheduled.
>> + */
>> + power_down = pch->active;
>> pch->active = false;
>> } else {
>> /* Make sure the PL330 Channel thread is active */
>>
>> ---
>> base-commit: aff5e6a77fc69a7c490246465940d18422d7c631
>> change-id: 20261028-pl330-runtime-pm-b5a30050b2f5
>>
>> Best regards,
>> --
>> Krzysztof Sokołowski <krzysiek.sokolowski@gmail.com>
>>
>>
Hello.
It is very interesting, but I have it for last month only in my private
repo, that has now public facing side to upstream fixes I have made .
My public repo: https://github.com/ksokolowski/rocknix-distribution/
Set of patches including this one are here:
https://github.com/ksokolowski/rocknix-distribution/commit/dd3923788d94588b8d5fdb602808b13370ab4208#diff-27b400675ba20f118e98f9a25b963ece2a2336d9ef1fc9416c273f507e24c271
Anyway, I can confirm it works fine on real hardware for last month. So
you can drop my patch and merge previous one as tested and confirmed to
work.
Krzysztof
^ permalink raw reply [flat|nested] 3+ messages in thread
end of thread, other threads:[~2026-10-28 17:03 UTC | newest]
Thread overview: 3+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2026-10-28 11:28 [PATCH] dmaengine: pl330: drop only the runtime PM reference a channel holds Krzysztof Sokołowski via B4 Relay
2026-10-28 14:35 ` Frank Li
2026-10-28 17:03 ` Krzysztof Sokołowski
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
all inboxes | Powered by JetHome®