* [PATCH] platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to
@ 2019-09-04 6:18 Jan Kiszka
0 siblings, 0 replies; only message in thread
From: Jan Kiszka @ 2019-09-04 6:18 UTC (permalink / raw)
To: Darren Hart, Andy Shevchenko, platform-driver-x86
Cc: Linux Kernel Mailing List
From: Jan Kiszka <jan.kiszka@siemens.com>
The SIMATIC IPC227E uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this device
to the critical systems list.
Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
---
Should go into stable as well, down to 4.19.
drivers/platform/x86/pmc_atom.c | 7 +++++++
1 file changed, 7 insertions(+)
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index aa53648a2214..9aca5e7ce6d0 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -415,6 +415,13 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
},
},
+ {
+ .ident = "SIMATIC IPC227E",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+ DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
+ },
+ },
{ /*sentinel*/ }
};
--
2.16.4
--
Siemens AG, Corporate Technology, CT RDA IOT SES-DE
Corporate Competence Center Embedded Linux
^ permalink raw reply [flat|nested] only message in thread
only message in thread, other threads:[~2019-09-04 6:18 UTC | newest]
Thread overview: (only message) (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2019-09-04 6:18 [PATCH] platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to Jan Kiszka
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Powered by JetHome