* [PATCH] iio: proximity: sx9310: report a hysteresis of 0 when it is disabled
@ 2026-10-26 10:00 Arnav Kapoor
2026-10-26 10:41 ` Andy Shevchenko
0 siblings, 1 reply; 2+ messages in thread
From: Arnav Kapoor @ 2026-10-26 10:00 UTC (permalink / raw)
To: Jonathan Cameron
Cc: David Lechner, Nuno Sá,
Andy Shevchenko, Andy Shevchenko, Stephen Boyd, linux-iio,
linux-kernel, Arnav Kapoor
sx9310_read_hysteresis() turns a PROXHYST value of 0 (no hysteresis)
into a shift of 0 and reports the full threshold, which writing back
then usually fails with -EINVAL. Report 0, as sx9324 and sx9360 do.
Fixes: 08f0411c48f2 ("iio: sx9310: Support setting hysteresis values")
Signed-off-by: Arnav Kapoor <kapoorarnav43@gmail.com>
---
Compile-tested only (W=1); I don't have SX9310 hardware.
drivers/iio/proximity/sx9310.c | 7 +++----
1 file changed, 3 insertions(+), 4 deletions(-)
diff --git a/drivers/iio/proximity/sx9310.c b/drivers/iio/proximity/sx9310.c
index 79ba46d8a0aa..80b9714caf39 100644
--- a/drivers/iio/proximity/sx9310.c
+++ b/drivers/iio/proximity/sx9310.c
@@ -447,10 +447,9 @@ static int sx9310_read_hysteresis(struct sx_common_data *data,
regval = FIELD_GET(SX9310_REG_PROX_CTRL10_HYST_MASK, regval);
if (!regval)
- regval = 5;
-
- /* regval is at most 5 */
- *val = pthresh >> (5 - regval);
+ *val = 0;
+ else
+ *val = pthresh >> (5 - regval);
return IIO_VAL_INT;
}
base-commit: 2ef6f5c4ee56e90c237c5f7687f09e635f7d30a9
--
2.53.0
^ permalink raw reply [flat|nested] 2+ messages in thread* Re: [PATCH] iio: proximity: sx9310: report a hysteresis of 0 when it is disabled
2026-10-26 10:00 [PATCH] iio: proximity: sx9310: report a hysteresis of 0 when it is disabled Arnav Kapoor
@ 2026-10-26 10:41 ` Andy Shevchenko
0 siblings, 0 replies; 2+ messages in thread
From: Andy Shevchenko @ 2026-10-26 10:41 UTC (permalink / raw)
To: Arnav Kapoor
Cc: Jonathan Cameron, David Lechner, Nuno Sá,
Andy Shevchenko, Stephen Boyd, linux-iio, linux-kernel
On Mon, Oct 26, 2026 at 03:30:32PM +0530, Arnav Kapoor wrote:
> sx9310_read_hysteresis() turns a PROXHYST value of 0 (no hysteresis)
> into a shift of 0 and reports the full threshold, which writing back
> then usually fails with -EINVAL. Report 0, as sx9324 and sx9360 do.
...
> regval = FIELD_GET(SX9310_REG_PROX_CTRL10_HYST_MASK, regval);
> if (!regval)
> - regval = 5;
> -
> - /* regval is at most 5 */
> - *val = pthresh >> (5 - regval);
> + *val = 0;
> + else
> + *val = pthresh >> (5 - regval);
While at it, invert the conditional.
if (regval)
*val = pthresh >> (5 - regval);
else
*val = 0;
--
With Best Regards,
Andy Shevchenko
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2026-10-26 10:41 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2026-10-26 10:00 [PATCH] iio: proximity: sx9310: report a hysteresis of 0 when it is disabled Arnav Kapoor
2026-10-26 10:41 ` Andy Shevchenko
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
all inboxes | Powered by JetHome®